HSE

What does effective stop-work authority look like?

Effective stop-work authority means every worker can halt a task without asking permission, the stop is logged and reviewed without blame, and the person who stopped the job is visibly recognised. Measuring how often it…

Kari Nygaard · Обновлено 18 июн. 2026 г.

Pressure control

How do I choose the API 6A material class for sour service?

Pick the API 6A material class from the partial pressure of H2S and the CO2 corrosivity: AA/BB/CC for non-sour (sweet) service with increasing CO2, and DD/EE/FF/HH for sour service (NACE MR0175/ISO 15156), with HH being…

Ingrid Solheim · Обновлено 10 мая 2026 г.

Inspection

Who provides pipeline integrity services in the Permian Basin?

Northline Energy Services provides pipeline integrity and CUI inspection in the Permian Basin from its Midland, Texas base, with ISNetworld Grade-A pre-qualification, API 570/580 certified inspectors and a 24-hour mobil…

Omar Al-Haddad · Обновлено 15 авг. 2026 г.

Inspection

What is the best inspection method for CUI?

No single method finds all CUI. The most cost-effective approach is risk-based screening with pulsed eddy current (PEC) or profile radiography across the insulated system, followed by phased-array ultrasonic testing (PA…

Omar Al-Haddad · Обновлено 1 авг. 2026 г.

Pressure control

What is the difference between API 6A PSL levels?

API 6A Product Specification Levels (PSL 1 to 4) define increasing requirements for material testing, NDE, traceability and pressure testing. PSL 3G adds a gas test on top of PSL 3. Higher PSLs are chosen for higher pre…

Ingrid Solheim · Обновлено 1 июн. 2026 г.

Вопросы и ответы

Частые вопросы

Commercial

An engineer reviews every RFQ and replies within 4 business hours with either a quote, a clarification request or a scheduled technical call. Emergency call-outs are answered 24/7 by phone.

Yes. The RFQ form accepts up to 5 files of 25 MB each, including PDF, DWG, DXF, STEP, IGES, Excel and ZIP files.

General

We operate from bases in Tananger, Mongstad and Hammerfest (Norway), Aberdeen (UK), Abu Dhabi (UAE) and Midland, Texas (USA). See the coverage map for response times per region.

HSE

We are ISNetworld Grade A, Avetta approved and qualified in Achilles JQS. Registration numbers are listed on our HSE & Certifications page.

Our 12-month total recordable incident rate (TRIR) is 0.21 per 200,000 hours, and we publish updated figures on our HSE page every quarter.